Abbott Plum 5000 Single Channel Infusion Pumps

Save Up to 80% on Abbott Plum 5000 Single Channel Infusion Pumps

Buy or rent pre-owned, recertified Abbott Plum 5000 Single Channel Infusion Pumps you need today. All pre-owned medical equipment is patient ready equipment and is covered by an OEM matched warranty.

Product Specifications

Dimensions:
approximately 18 x 23 x 23 cm (7 x 9 x 9 in), excluding pole clamp protrusion and power cord storage
Weight:
approximately 6.0 Kg (13 lb), with battery
Casing:
High-impact plastic
Power Requirements:
110-120 VAC, 50/60 Hz, 30 W
Power Cord:
Hospital-grade AC cord. 8 ft long, with transparent Plug and retainer plate
Fuses:
0.5 A, 250 V, Slow Blowing
Battery:
One sealed, lead-acid, rechargeable 8 V battery, Internal to device. Accessible for ease of field replacement, with color-coded leads and polarized connector
Battery life (new batteries, full charge, at 20 C):
Approximately 500 mL total volume delivered or six hours of operation, whichever occurs first
Delivery Rate Range:
Micro Mode: 0.1 to 99.9 mL/hr (in o.1 mL increments) The total of the primary rate plus the secondary rate cannot exceed 99.9 mL/hr in Micro Mode Note: while using the concurrent delivery feature in the Micro Mode, neither the primary rate nor the secondary rate can be less than 0.5 mL/hr Macro Mode: 1 to 999 mL/hr (in 1 mL increments the total of the primary rate plus the secondary rate cannot exceed 700 mL/) in 1 mL/hr in Macro Mode
Dose Limit Range:
Micro Mode: 0.1 to 999 mL (in 0.1 mL increments) Macro Mode: 1 to 9999 mL (in 1 mL increments)
Operating Backpressure:
Pressure: -2 to 10 psig. The maximum pressure is user-selectable from 1 to 10 psig, via the front panel touch switches Secondary Doses: For dual-channel delivery, a single dose of a secondary fluid may be administered For multidose delivery, 1 to 24 doses of a secondary fluid may be administered at intervals from 15 minutes to 24 hours
Occlusion Alarm:
Distal: the Distal Occlusion alarm sounds within two pumping cycles after the distal set tubing or set outlet fitting becomes occluded Proximal: the Proximal Occlusion alarm sounds within five pumping cycles if the tubing proximal to the cassette becomes occluded Air-in-Alarm: the Stopped Air In Distal Line alarm will sound if a bubble 100 uL or larger passes the distal air-in-line sensors (alarm may actually sound at detection of a bubble as small as 50 uL) Proximal: the Stopped Air In Proximal Line alarm will sound if approximately 1200 uL or more passes through the proximal air-in-line sensors