Baxter Sigma Spectrum Single Channel Infusion Pumps

Save Up to 80% on Baxter Sigma Spectrum Single Channel Infusion Pumps

Buy or rent pre-owned, recertified Baxter Sigma Spectrum Single Channel Infusion Pumps you need today. All pre-owned medical equipment is patient ready equipment and is covered by an OEM matched warranty.

Specifications

AC Power:
AC Power Adapter, low profile, covers only one outlet, Medical Grade (EN60601-1-2); 10oz

Pump Size (with standard battery):
Without IV pole clamp – 5.8” H x 4.2” W x 2.5” D
With IV pole clamp – 5.8” H x 6.4” W x 4.7” D

Pump Size (with wireless battery module):
Without IV pole clamp – 6.3” H x 4.2” W x 2.5” D
With IV pole clamp – 6.3” H x 6.4” W x 4.7” D

Pump Weight (with standard battery):
Without IV pole clamp – 25.5 oz ±1.0 oz
With IV pole clamp – 33.5 oz ±1.0 oz

Pump Weight (with wireless battery module):
Without IV pole clamp – 26.5 oz ±1.0 oz
With IV pole clamp – 34.5 oz ±1.0 oz

Anti-Free-Flow System:
Set based, utilizing IV set slide clamp

Display:
color

Maximum Pump Pressure:
28 PSI

Occlusion Pressure:
Adjustable: High (19 ±9 PSI), Medium (13 ±6 PSI), and Low (6 ±4 PSI)

Infusion Modes:
Primary and Secondary, Multi-Step, and Cyclic TPN

Flow Rate:
0.5 to 999 mL/hr with 0.1 mL/hr increments from 0.5 to 99.9 mL/hr and 1.0 mL/hr increments from 100 to 999 mL/hr

Total Volume:
0.1 to 999 mL with 0.1 mL increments from 0.1 to 99.9 mL and 1.0 mL increments from 100 to 999 mL

KVO:
The default KVO rate is set at 1 mL/hr but may be configured to between 0.5 – 50 mL/hr

Dose Modes (Continuous Infusions):
mL/hr, mL/kg/min, mL/kg/hr, g/hr, mg/hr, mg/kg/hr, mg/min, mg/kg/min, mg/kg/day, mcg/hr, mcg/kg/hr, mcg/min, mcg/kg/min, mcg/kg/day, ng/min, ng/kg/min, Units/hr, Units/kg/hr, Units/min, Units/kg/min, mUnits/min, mUnits/kg/hr, mUnits/kg/min, mEq/hr, mEq/kg/hr, mmol/hr, mmol/kg/hr

Pumping Mechanism:
Linear peristaltic

Alarms and Alerts:

Alarm Volume:
Variable (three levels: high, medium and low)

Air-In-Line:
Dual beam ultrasonic detector alarms for large bubbles but allows smaller bubbles to pass. Detects air bubbles > 1” (» 125μL Hospira, » 140μL Baxter), will alarm if > 1 mL* of air in 15 min., < 50μL bubbles are omitted in the summation of the 1 mL.* *up to 1.5 mL at 60°F

Downstream Occlusion:
Automatic restart occurs after the downstream occlusion is cleared. Actuation can be set to Low, 6 ±4 PSI, Medium, 13 ±6 PSI or High, 19 ±9 PSI

Very Low Battery:
≤15 minutes of battery power remain

Due for inspection:
Preventative Maintenance and/or Network Certification

Logging Memory:
While not in use, the pump’s memory will retain the last programmed setup screen for 24 hours
Separate pump history log and drug event log
10,000 ± event capacity. Once the maximum number of log entries is reached, the data for each new event replaces the data for the oldest event (the data for oldest event is lost)