Hospira Gemstar Ambulatory Infusion Pumps

Save Up to 80% on Hospira Gemstar Ambulatory Infusion Pumps

Buy or rent pre-owned, recertified Hospira Gemstar Ambulatory Infusion Pumps you need today. All pre-owned medical equipment is patient ready equipment and is covered by an OEM matched warranty.

Specifications

Dimensions:
Height: 5.7 in. (14.5 cm)

Width:
3.8 in. (9.7 cm)

Depth:
2.0 in. (5.1 cm)

Weight:
Approximately 18 oz. (526 grams) excluding batteries

Power Sources:
AC Mains: Wall-mount AC mains adaptor; 6 ft. (1.8 m) cord molded plug
Input: 110 VAC
Output: 3.0 VDC

Tabletop: AC mains adaptor; molded plug
Input: 100–240 VAC
Output: 3.0 VDC

Battery:
Two disposable AA alkaline batteries

Battery Pack:
Lithium-ion rechargeable battery (using GemStar® AC mains adapter)

Docking Station:
Mounts on an I.V. pole; 10 ft. (3 m) cord
Input: 100–240 VAC
Output: 3.0 VDC
Internal lithium ion rechargeable battery

Power Capacity
Using two fresh, disposable AA batteries or a charged battery pack, at temperature between 59° F and 95° F (15° C and 35° C), the pump is capable of delivering approximately:
96 hours at rates below 5 mL/hr
48 hours at rates at or above 5 mL/hr but below 25 mL/hr
24 hours at rates at or above 25 mL/hr but below 125 mL/hr
3000 mL at a rate of 125 mL/hr or higher

Pump Mechanism:
Volumetric, Piston Driven

Memory Protection:
Current program and 400-event (history) log protected by internal battery-backed memory for at least one year after power is removed

Operating Controls:
One 23-key keypad; bolus, data port, and AC mains jacks; bolus button

External Power LED:
Green LED marked with plug icon lights continuously when pump is connected to AC mains power Green LED flashes when pump is connected to external batteries

Alarm LED:
Red LED marked with alarm icon lights during alarm conditions

Audible Alarm:
The audible alarm is user-adjustable from the maximum volume down to silent
The alarm cannot be turned off completely. The alarm automatically reverts to the maximum volume if the user does not respond within one minute

Display:
Backlit, four-line-by-sixteen-character alphanumeric graphics display
Backlight on AC: Continuous
Backlight on Batteries: Continuous during programming, program review, and history display; otherwise activated by keypress or alarm; not activated by bolus request

Real Time Clock:
Accuracy of ±5 minutes per month or better at temperatures between 59° F and 95° F (15° C and 35° C)

Print Function:
Port & Interface: RS-232 serial interface port (data port), minimum baud rate of 2400, isolated circuit Printers: Seiko DPU 414 or compatible serial printer

System Accuracy:
Continuous: ± 10% for rates of 0.1 mL to less than 5 mL/hr ± 5% for rates of 5 mL to 1000 mL/hr

Air Sensitivity:
ON: Pump alarms at approximately 0.5 mL of air Alarms for any bubble greater than 500 microliters with a tolerance of 200 microliters 2 mL: Pump alarms at approximately 2 mL of air Alarms when pump detects 2.0 +1.0/-0.2 mL of air in 6 mL of total volume delivered
OFF: Alarm is not activated Recommend using air-eliminating filter when Air Sensitivity is set OFF

Occlusion Sensitivity:
Distal Occlusion: Alarms when pump detects distal pressure within a selectable range:
Low: 7 psi (48 kPa) ± 5 psi (±34 kPa)
Medium: 12 psi (83 kPa) ±8 psi (±55 kPa)
High: 26 psi (179 kPa) ±14 psi (±96 kPa)
Proximal Occlusion: Alarms when pump detects proximal pressure less than or equal to -4 psi (-28 kPa)